ASTM

ASTM D2867-23 82 PDF Download

Click here to purchase

1.1 These test methods provide three procedures for the determination of the moisture content of activated carbon. The procedures may also be used to dry samples required for other tests. The oven drying and moisture balance methods are used when water is the only volatile material present and is in significant quantities, and the activated carbon is not heat sensitive (some activated carbons can ignite spontaneously at temperatures as low as 150 °C). The xylene extraction method is used when a carbon is known or suspected to be heat sensitive or to contain miscible organic compounds instead of or in addition to water. The interferences posed by miscible inorganic compounds has not been determined. The oven drying method described in these test methods may be used as the reference for development of instrumental techniques for moisture determination in activated carbon.

Product Details

Published:
04/01/2023
Number of Pages:
5
File Size:
1 file , 290 KB
Redline File Size:
2 files , 410 KB
Note:
This product is unavailable in Russia, Ukraine, Belarus